Click the WhatsApp button to chat, or leave a message, and we will contact you within 12 hours.
G4-110 Bosch PDE IVECO Detroit Unit Injector Repair Kit Lift Gauge Shim Kit




Bosch PDE electronic unit injectors are driven by the engine camshaft and metered by a solenoid on top of the pump body. Unlike a common rail injector, there is no rail pressure to lean on when the unit is rebuilt: fuel delivery and timing are set by mechanical shims inside the injector, and the only way to know which shim belongs in a unit is to measure its armature lift and needle lift on the bench. The G4-110 kit is built around that measurement.
Digital lift gauge — dial indicator with a digital readout for measuring injector lift in fine increments, so the shim can be chosen from a measured number instead of by trial.
ATS-AR28 measuring block — machined block that locates the injector body and holds the gauge stem square against the part being measured.
Injector clamping fixture — bracket that clamps the PDE body in the correct attitude so the solenoid and nozzle ends stay accessible.
Push pin and adapters — probe pin and the small blocks and bushes needed to reach the measuring face on different PDE body styles.
Nozzle needle shim set — assorted thicknesses across the 1.00 to 2.00 mm range for setting needle lift.
Solenoid spring shim sets — A set across the 0.80 to 0.60 mm range and B set across the 0.60 to 0.40 mm range for setting the solenoid armature travel.
The reference numbers marked on the case cover Bosch PDE units in the 0 414 703 series. These units are fitted to Detroit Diesel Series 60 engines and to IVECO trucks in the Stralis and Trakker ranges with Cursor engines, and the same injector family is used on Case IH and New Holland equipment built on those FPT engines. If you are working on a different engine, send us the number stamped on the injector and we will tell you whether the kit covers it.
Clamp the injector in the fixture so the solenoid end and the nozzle end are both reachable.
Fit the ATS-AR28 block and the push pin, then zero the digital gauge on the reference face.
Measure the armature lift and the needle lift and write both numbers down against the injector serial.
Pick the shim thickness from the measured value using the injector data you are working to, and fit it.
Re-measure after assembly to confirm the lift has landed where it should before the unit goes back into the engine.
A PDE unit is only as good as its shim stack. A needle shim that is one step too thick holds the needle off its seat and the unit smokes; one step too thin and the needle lift is short, so delivery falls away at high load. On the solenoid side the spring shims set how far the armature travels, and that travel decides how cleanly the valve opens and closes. Having the full thickness range in the case in fine steps means the unit can be brought back to the number that was measured, not to the nearest shim that happened to be on the shelf.
Tell us the engine model and the number stamped on the injector you are rebuilding, and we will confirm that the fixture and measuring block suit that body style, and that the shim sets match the thickness steps you need. Our team also answers questions on PDE teardown and on measuring procedure, and we can quote the shim sets separately if you only need to restock one range.
The reason this kit exists as a set and not as a loose gauge is repeatability. A PDE injector that is rebuilt with the wrong shim will still start and idle, so the fault only shows up later as smoke, a misfire under load, or a unit that will not make its delivery. Measuring the lift with a dedicated block and a digital gauge, and recording the number against the injector, turns the rebuild into a documented procedure that can be repeated on the next unit from the same engine.
Needle shims run from 1.00 up to 2.00 mm, the solenoid spring A set covers 0.80 down to 0.60 mm and the B set covers 0.60 down to 0.40 mm. Keeping all three ranges together means a unit can usually be brought back into specification without ordering a single thickness, and the used shims can be sorted back into the case for the next job.
Clean the injector before it goes into the fixture: grit on the measuring face will read as lift error and lead to the wrong shim. Zero the gauge on the same reference every time, and record the room temperature if you are comparing results between sessions. Always re-measure after assembly rather than trusting the calculated value.
| Part Number | G4-110 |
| Product Name | Bosch PDE Unit Injector Repair Kit |
| Brand | Beacon |
| Application | Bosch PDE electronic unit injectors, 0 414 703 series (Detroit Diesel Series 60, IVECO Stralis and Trakker with Cursor engines, Case IH and New Holland FPT engines) |
| Includes | Digital lift gauge, ATS-AR28 measuring block, injector clamping fixture, push pin and adapters, nozzle needle shim set, solenoid spring shim sets A and B |
| Nozzle Needle Shims | 1.00 to 2.00 mm range |
| Solenoid Spring Shims | A set 0.80 to 0.60 mm, B set 0.60 to 0.40 mm |
| Package | Blow-moulded carrying case with fitted foam insert |